FLIR G620a

Fixed-Mount Hydrocarbon/VOC Optical Gas Imaging (OGI) Camera

Find gas leaks while meeting governmental and environmental emission goals with the FLIR G620a: a long-lived, cooled OGI camera solution for continuous monitoring at upstream and midstream gas production and processing facilities. The G620a is spectrally filtered to see methane (CH₄), hydrocarbons, and Volatile Organic Compounds (VOCs) with a performance OGI detector that meets sensitivity requirements set forth in U.S. EPA OOOOa and Appendix K. Small and lightweight, the G620a installs quickly and relies on a simplified web interface. Never miss a moment of monitoring thanks to the robust linear cooler which supports 27,000 hours of non-stop operation. The FLIR G620a can help oil and gas companies maintain valuable capital equipment, avoid product loss, meet emissions reduction metrics, and ensure safer work practices.

Unmatched image clarity

The high-resolution, high sensitivity cooled image sensor plus the advantage of FLIR’s proprietary High Sensitivity Mode (HSM) allows users to visualize even the smallest gas leaks.

FLIR G620a cameras offer more than 27,000 hours of runtime before any service is required (mean time to failure).

Satisfy U.S. EPA methane and VOC detection sensitivity requirements and achieve global ESG pledges for methane and hydrocarbon reduction.

FLIR G620a Fixed-Mount Hydrocarbon/VOC OGI Camera – Full Specifications

Imaging & Optical Specifications

IR Resolution 640 × 512
Thermal Sensitivity (NETD) < 15 mK at 25°C
Spectral Range 3.2 – 3.4 µm
Detector Type High Operating Temperature (HOT) MWIR T2SLS
Detector Pitch 15 µm
Digital Image Enhancement High Sensitivity Mode (HSM)
Field of View (FOV) G620a 6°: 6.0° × 4.8°
G620a 14.5°: 14.4° × 11.5°
G620a 24°: 23.6° × 19.0°
Focal Length G620a 6°: 92 mm
G620a 14.5°: 38 mm
G620a 24°: 23 mm
Minimum Focus Distance G620a 6°: 2 m (6.6 ft)
G620a 14.5°: 0.5 m (1.64 ft)
G620a 24°: 0.3 m (1.0 ft)
Image Frequency 30 Hz
Image Modes IR image, High Sensitivity Mode (HSM)
Zoom Digital zoom: 1×, 2×, 4×, 8×
Video Streaming Non-radiometric IR video streaming via RTSP (H.264/MJPEG)
Radiometric Video/Recording None

Measurement & Analysis

Temperature Range -10°C to 120°C
Measurement Accuracy ≤ 100°C ±2°C, >100°C ±2% of reading
Gas Sensitivity (NECL)* NECL 1m, ΔT 10°C:
Methane: 16 ppm × m
Hydrocarbons (Niabara mix): 6.4 ppm × m
Ambient Drift Compensation Yes (factory calibrated)

Communication & Data Storage

Control Interface GigE Vision (GenICam); RTSP; Web interface; REST API
Digital Inputs 2× opto-isolated (Vin low: 0–1.5 V, Vin high: 3–25 V)
Digital Outputs 3× opto-isolated outputs (0–48 VDC, max. 350 mA), 1 default NC
Synchronization Sync In

Power

Primary Power Source Power over Ethernet (PoE+) Type 2 (min. 30 W)
Optional DC Power M12 12-pin A-coded male (shared with Digital I/O)
Power Consumption 25 W (cooling)
DC Voltage Range 18 V – 56 V

General & Physical

Dimensions (Without Lens) 200 × 76 × 92 mm (7.9 × 3.0 × 3.6 in)
Dimensions (With Lens) 6° lens: 297 × 99 × 99 mm (11.7 × 3.9 × 3.9 in)
14.5° & 24° lenses: 229 × 76 × 95 mm (9.0 × 3.0 × 3.8 in)
Weight 6°: 1.90 kg (4.14 lb)
14.5°: 1.48 kg (3.22 lb)
24°: 1.50 kg (3.27 lb)
Weight (Without Lens) 1.32 kg (2.91 lb)

Environmental & Certifications

Operating Temperature Range -20°C to 50°C (-4°F to 122°F)
Encapsulation IP50
Shock (MIL-STD-810H) 25 g, 6 ms; half-sine; ±500 shocks (X,Y,Z)
Vibration 10–58 Hz, 0.15 mm; 58–500 Hz, 2 g; 5 cycles, 1 oct/min (X,Y,Z)
EMC / Directives EN55032:2015/A11:2020, EN55035:2017/A11:2020, FCC Part 15 Class A, KC C 9832 & KS C 9835

Specifications are subject to change without notice. FLIR and G620a are trademarks of Teledyne FLIR LLC. :contentReference[oaicite:1]{index=1}